Bourdon Haenni Oil pressure gauge
DPC100
Nominal size: 100 mm
Approval: ATEX II2GDc-IM2c, Gost
Welded with blow-out disc, back
For gaseous and liquid, aggressive, high and low visconsity media
High overpressure safety
Technical Data
MAT1
Nominal size: 40 mm
Measuring range: 1... 0 to 0... 400 bar
Conform to EN 837-1 standard
Pressure Directive PED 97/23/CE
Technical Data
MAT2
Nominal size: 50 mm
Measuring range: 1... 0 to 0... 400 bar
Conform to EN 837-1 standard
Pressure Directive PED 97/23/CE
Technical Data
MAT3
Nominal size: 63 mm
Measuring range: 1... 0 to 0... 400 bar
Conform to EN 837-1 standard
Pressure Directive PED 97/23/CE
Technical Data
MAT5
Nominal size: 100 mm
Measuring range: 1... 0 to 0... 400 bar
Conform to EN 837-1 standard
Pressure Directive PED 97/23/CE
Technical Data
MCD7
Nominal size: 150 mm
Measuring range: 0 ... 10 mbar to 0 ... 250 mbar
For non corrosive gases and aggressive environment
Safety valve on high pressure side
Technical Data
MCX5
Nominal size: 100 mm
Measuring ranges: 0 ... 10 mbar to 0 ... 600 mbar
Low pressure measurements
High overpressure protection
Suitable for corrosive gases
Technical Data
MCX7
Nominal size: 150 mm
Measuring ranges: 0 ... 6 mbar to 0 ... 600 mbar
Low pressure measurements
High overpressure protection
Suitable for corrosive gases
Technical Data
MEX2
Nominal size: 50 mm
Approval: ATEX II2GDc-IM2c, Lloyd's Register, Gost
For corrosive gases and liquids
Fully welded process connection
Technical Data
MEX3 / MEM3
Nominal size: 63 mm
Approval: ATEX II2GDc-IM2c, Lloyd's Register, Gost
For corrosive gases and liquids
Fully welded process connection
Technical Data
MEX5 / MEM5
Nominal size: 100 mm
Approval: ATEX II2GDc-IM2c, Lloyd's Register, Gost
For corrosive gases and liquids
Fully welded process connection
Technical Data
MEX8
Nominal size: 160 mm
Approval: ATEX II2GDc-IM2c, Lloyd's Register, Gost
For corrosive gases and liquids
Long term reliability
Technical Data
MIT3
Nominal size: 63 mm
Measuring range: -1... + 0 to 0...+ 1000 bar
Stainless steel case
Anti-vibrating system
Technical Data
MIT5
Nominal size: 100 mm
Measuring range: -1 ... + 0 to 0 ...+ 1000 bar
Stainless steel case
Anti-vibrating system
Technical Data
MIX7 / MIM7
Nominal size: 150 mm
Approval: ATEX II2GDc-IM2c, Lloyd's Register, Gost
For corrosive gases and liquids
Long term reliability
Technical Data
MMF7
Nominal size: 150 mm
Measuring range: -1 ... 0 to 0 ... 600 bar
Can be used in corrosive gases and liquids that are not crystallizing
Approval: Lloyd's Register
Technical Data
MMJ7
Nominal size: 150 mm
Measuring range: -1 ... 0 to 0 ... 600 bar
For corrosive gases and liquids
Class 1 according to EN 873-1
Technical Data
MMN5
Nominal size: 100 mm
Approval: ATEX II2GDc-IM2c, Lloyd's Register, Gost
For corrosive atmospheres and fluids
Long term reliability
Safety version S3 according to EN837-1
Technical Data
MMX1
Nominal size: 40 mm
Approval: ATEX II2GDc-IM2c
For corrosive gases and liquids
Fully welded process connection
Technical Data
MPF6 / MPJ6
Nominal size: 130 mm (4.5")
Approval: Gost
For corrosive gases and liquids
With or without damping fluid
Technical Data
MTA2
Nominal size: 50 mm
Measuring ranges: 0 ... 60 mbar to 0 ... 600 mbar
Low pressure measurements
for clean and non-corrosive gases
Technical Data
MTA3
Nominal size: 63 mm
Measuring ranges: 0 ... 60 mbar to 0 ... 600 mbar
Low pressure measurements
for clean and non-corrosive gases
Technical Data
MTA5
Nominal size: 100 mm
Measuring ranges: 0 ... 16 mbar to 0 ... 600 mbar
Low pressure measurements
for clean and non-corrosive gases
Technical Data
RT2E
Compact temperature switch
Approval: ATEX EEx d
Godd vibration resistance
Measuring ranges: -40...+350°C
Stem 9.0 mm (rigid or with capillary)
Technical Data
RT2N
Compact temperature switch
Good vibration resistance
Measuring ranges: -40...+350°C
Stem 9.0 mm (rigid or with capillary)
Technical Data
RT2Y
Compact temperature switch
Approval: ATEX EEx ia
Godd vibration resistance
Measuring ranges: -40...+350°C
Stem 9.0 mm (rigid or with capillary)
Technical Data
RTN
Standard temperature switch
Adjustable setpoint(s) and deadband
Measuring ranges: -40...+350°C
Stem 14mm (rigid or with capillary)
Technical Data - direct mounting
Technical Data - with capillary
RTNE
Standard temperature switch
Approval: ATEX EEx d
Adjustable setpoint(s) and deadband
Measuring ranges: -40...+350°C
Stem 14mm (rigid or with capillary)
Technical Data - direct mounting
Technical Data - with capillary
RTNY
Standard temperature switch
Approval: ATEX EEx ia
Adjustable setpoint(s) and deadband
Measuring ranges: -40...+350°C
Stem 14mm (rigid or with capillary)
Technical Data - direct mounting
Technical Data - with capillary
TB40 + TB63 Series
Bi-metal thermometer
∅40mm, ∅63 mm
-30...+500°C
Industrial standard type
Technical Data
TB80 + TB100 + TB160 Series
Bi-metall thermometer
∅80 mm, ∅100 mm, ∅160 mm
-30...+500°C
Industrial standard type
Technical Data
TBH Series
Bi-metall thermometer
∅80 mm, ∅100 mm
-20...+250°C
Short immersion tube
Technical Data
TBHA Series
Bi-metall thermometer
∅80 mm, ∅100 mm
-20...+160°C
Clamp-on thermometer
Technical Data
TBHI Series
Bi-metall thermometer
∅100 mm, ∅130 mm
-70...+600°C
Heavy industry version, IP68
Technical Data
TBI Series
Bi-metall thermometer
∅80...160 mm
-20...+250°C
Stainless steel, IP67
Technical Data
TBL Series
Bi-metal thermometer
Ø100mm
-30...+80°C
For ventilation systems
Technical Data
TBX / TBW Series
Bi-metall thermometer
∅80...160 mm
-30...+80°C
Conical immersion tube
Technical Data
TSF Series
Gas filled thermometer
∅ 63...250 mm
-200...+800 °C
Remote measurement
Technical Data
TSFE Series
Gas filled thermometer
∅ 100 mm, ∅ 160 mm
-200...+800°C
Remote measurement with contact
Technical Data
TSS Series
Gas filled thermometer
∅ 63...250 mm
-200...+800 °C
Direct measurement
Technical Data
TSSE Series
Gas filled thermometer
∅ 100 mm, ∅ 160 mm
-200...+800°C
Direct measurement with contact
Technical Data
1500
Longitudinal starshaped seal with treaded process connection
0…2,5 bar to 0….1000 bar
Compact design with large diaphragm
Stainless steel
Technical Data
1510
Longitudinal starshaped seal with union nut
0…2,5 bar to 0….1000 bar
Compact design with large diaphragm
Stainless steel
Technical Data
1520
In line seals for hygienic applications
Threaded connection according to SMS 1146
0…1,6 bar to 0…40 bar
No dead volume
Stainless steel
Technical Data
1530
In line seals for hygienic applications
Threaded connection according to SMS 1146
0…1,6 bar to 0…40 bar
No dead volume
Stainless steel
Technical Data
1540
In line seals for hygienic applications
Threaded connection according to Naue
0…1,6 bar to 0…40 bar
No dead volume
Stainless steel
Technical Data
1620
In line seals for hygienic applications
Clamp connection according to DIN 32676 or ISO 2852
0…1,6 bar to 0…40 bar
No dead volume
Stainless steel
Technical Data
1650
In line seals for the process industry
Sandwich type for mounting between flanges
0…1,6 bar bis 0…250 bar
No dead volume
Stainless steel, optional with coating
Technical Data
D030
Screwed diaphragm seal, plastic
0…2,5 bar to 0…10 bar
Suitable for very aggressive media
No metallic parts in contact with the medium
Technical Data
D04x
Screwed diaphragm, stainless steel
0…1 bar to 0…400 bar
Robust and compact
Fully welded design
Technical Data
D05x
Screwed diaphragm seal, flush mounted
0…1 bar to 0…600 bar
Flush diaphragm for highly viscous media
Stainless steel
Compact design
Technical Data
D4xx
Flange seal, diaphragm not flush
0…160 mbar to 0…420 bar
Flange connection according to EN 1759-1, ASME B16.5, EN1092-1
Stainless steel and exotic materials
Option: Cleaning ring
Technical Data D400
Technical Data D418
Technical Data D438
D6xx
Seal with extended flange
0…160 mbar to 0…160 bar
Flange connection according to EN 1759-1, ASME B16.5, EN1092-1
Stainless steel and exotic materials
Option: Cleaning ring
Technical Data
D801
Diaphragm seal, cell type
0…160 mbar to 0…400 bar
Stainless steel and exotic materials
Technical Data
D82x
Flange seal, flush diaphragm
0…160 mbar to 0…420 bar
Flange connection according to EN 1759-1, ASME B16.5, EN1092-1
Stainless steel and exotic materials
Option: Cleaning ring
Technical Data D820
Technical Data D821
Technical Data D824
Technical Data D825
D850
Flange type with extended diaphragm
0…160 mbar to 0…40 bar
Extension 50, 100 or 150 mm
Stainless steel and exotic materials
Technical Data
D912
Process seals for transmitters
0…10 mbar to 0…250 bar
Pressure, level or flow measurement
Stainless steel and exotic materials
High temperature resistant
Technical Data D912
Technical Data D914
Technical Data D918
Technical Data D944
DADF
Diaphragm seal according to DIN 11851 with treaded socket
0…1 bar to 0…40 bar
Stainless steel or Hastelloy
3A, FDA
Technical Data
DADL
Diaphragm seal according to DIN 11851 with union nut
0…1 bar to 0…40 bar
Stainless steel or Hastelloy
3A, FDA
Technical Data
DAEF
Diaphragm seal according to SMS 1145 with threaded socket
0…1 bar to 0…40 bar
Stainless steel or Hastelloy
3A, FDA
Technical Data
DAEL
Diaphragm seal according to SMS 1145 with union nut
0…1 bar to 0…40 bar
Stainless steel or Hastelloy
3A, FDA
Technical Data
DANC
Clamp connection according to DIN 32676 or ISO 2852
0…1 bar to 0…40 bar
Stainless steel or Hastelloy
3A, FDA
Technical Data
DAVA
Diaphragm seal with Varivent® connection
0…1 bar to 0…40 bar
Stainless steel or Hastelloy
3A, FDA
Technical Data
DT1-DT2-DT3-DT5-DT8
Screwed diaphragm seal, threaded
0…160 mbar to 0…1000 bar
Stainless steel and exotic materials
Option: Cleaning ring
Technical Data
RDE
Differential pressure switch
Approval: ATEX EEx d
Adjustable setpoint(s) and deadband
Measuring range: -2.5...2.5 mbar to 2.5...30 bar
Overpressure / Static pressure: 0.15 to 220 bar
Technical Data RDE4
Technical Data RDE5
Technical Data RDE6
Technical Data RDE8
RDxx
Differential pressure switch
Adjustable setpoint(s) and deadband
Measuring range: -2.5...2.5 mbar to 2.5...30 bar
Overpressure / Static pressure: 0.15 to 220 bar
Technical Data RDN4
Technical Data RDN5
Technical Data RDN6
Technical Data RDN8
RDY
Differential pressure switch
Approval: ATEX EEx ia
Adjustable setpoint(s) and deadband
Measuring range: -2.5...2.5 mbar to 2.5...30 bar
Overpressure / Static pressure: 0.15 to 220 bar
Technical Data RDY4
Technical Data RDY5
Technical Data RDY6
Technical Data RDY8
RP2E
Pressure switch with ATEX EEx d approval
Good resistance to vibrations and overpressure
Measuringe range: 0...1 to 0...100 bar
Overpressure / Static pressure: max 200 bar
Technical Data
RP2N
Standard pressure switch
Good resistance to vibration and overpressure
Measuring range: 0...1 to 0...100 bar
Overpressure / Static pressure: max. 200 bar
Technical Data
RP2Y
Pressure switch with ATEX EEx ia approval
Good resistance to vibrations and overpressure
Measuringe range: 0...1 to 0...100 bar
Overpressure / Static pressure: max 200 bar
Technical Data
RPPE
Pressure switch for low and high pressure
Approval: ATEX EEx d
Adjustable setpoint(s) and deadband
Measuring range: -50...0 mbar to 60...600 bar
Overpressure / Static pressure: max. 800 bar
Technical Data RPPE3
Technical Data RPPE4
Technical Data RPPE6
Technical Data RPPE7
Technical Data RPPE8
RPPN
Pressure switch for low and high pressure
Adjustable setpoint(s) and deadband
Measuring range: -50...0 mbar to 60...600 bar
Overpressure / Static pressure: max. 800 bar
Technical Data RPPN7
Technical Data RPPN8
RPPY
Pressure switch for low and high pressure
Approval: ATEX EEx ia
Adjustable setpoint(s) and deadband
Measuring range: -50...0 mbar to 60...600 bar
Overpressure / Static pressure: max. 800 bar
Technical Data RPPY3
Technical Data RPPY4
Automation
Contact Contact Us
Fax:0084-024-66644590
Tel:0084-024-66644591
Email:sales@big-tree.vn
Add:No.37,Lane 209,Alley 173/37,AnDuongVuong Street,PhuThuong Ward,TayHo District,HaNoi City.